3-22 Motion Mate DSM314 for Series 90-30 PLCs User's Manual
January 2001 GFK-1742A
3
strain relief and as cable shield ground. The outer insulation of the Digital servo amplifier cable
must be removed to expose the cable shield in the contact area of the clamp.
40 (1.57)
to
80 (3.15)
able
Cable
Grounding
Clamp
G
rounding
B
ar
Figure 3-12. Detail of Cable Grounding Clamp A99L-0035-0001
Figure 3-13. . 44B295864-001 Grounding Bar, Side View Dimensions